  • 1,000A molded case circuit breaker, ABB SACE Tmax series
  • 3-pole, fixed-mount configuration with front terminals
  • PR231/P LS/I electronic trip unit — overload, short-circuit (delayed), and instantaneous protection
  • Breaking capacity: 36–50 kA @ 415–480V AC
  • Rated operational voltage: up to 690V AC, 50/60 Hz
  • IEC 60947-2 listed

Key Features:

  • 1,000A continuous rated capacity, 3-pole, fixed-mount with front terminals
  • Rated operational voltage up to 690V AC; rated insulation voltage 1,000V
  • Rated impulse withstand voltage: 8 kV
  • Breaking capacity (Icu): 50 kA @ 415V AC / 36 kA @ 480V AC (S performance class)
  • PR231/P LS/I electronic solid-state trip unit providing three-tier protection:
    • L — overload protection with long-time inverse delay (adjustable 0.4–1 x In)
    • S — short-circuit protection with selectable delayed trip (adjustable 1–10 x In, inverse time I²t curve)
    • I — instantaneous short-circuit protection (adjustable 1–10 x In)
  • Selectable S or I short-circuit protection mode via front dip-switch
  • Neutral protection threshold adjustable to OFF, 50%, or 100% of phase setting via front dip-switch
  • Dip-switch programmable settings directly accessible from the front panel — no tools required
  • Trip unit powered by current transformers — operates reliably even under single-phase load conditions
  • Available in fixed, plug-in, and withdrawable versions; this unit is fixed configuration
  • Wide range of compatible accessories including shunt trips, auxiliary contacts, and alarm contacts
  • Conforms to IEC 60947-2, CE Low Voltage Directive, and EMC Directive 2004/108/CE

Applications:

  • Large commercial and industrial power distribution panels and switchgear
  • Generator set output protection and main breaker applications
  • Motor control centers (MCC) and main distribution boards
  • Transformer and feeder protection in primary distribution systems
  • Data centers, hospitals, and mission-critical power infrastructure
  • Marine and industrial plant power systems

Electrical Specifications:

  • Rated Current (In): 1,000A
  • Poles: 3
  • Rated Operational Voltage (Ue): Up to 690V AC
  • Rated Insulation Voltage (Ui): 1,000V
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Breaking Capacity (Icu): 50 kA @ 415V AC / 36–50 kA @ 415–480V AC
  • Trip Unit: PR231/P LS/I (electronic solid-state)
  • Frequency: 50/60 Hz
  • Mounting: Fixed
  • Dimensions: 5″ L x 4″ W x 7″ H | Weight: 15 lbs