Thomson TS870 | 1200A 3-Phase Automatic Transfer Switch SKU: TS870 1200A

  • 1,200A automatic transfer switch, three-phase, non-service entrance rated
  • Open transition (break-before-make) operation with optional closed transition
  • TSC 7320 digital controller with backlit LCD display and programmable inputs/outputs
  • UL 1008 and CSA C22.2 No. 178 listed
  • NEMA 1 standard enclosure; optional NEMA 3R outdoor enclosure available

Key Features:

  • 1,200A continuous rated capacity, three-phase, up to 600VAC, 3-wire or 4-wire systems
  • Non-service entrance rated — upstream molded case circuit breakers or fuses with overcurrent protection required on both utility and generator sides
  • Two mechanically interlocked power switching units for inherent source separation and reliable operation
  • Fully enclosed silver alloy contacts providing high withstand rating and 100% continuous current rating
  • Open transition (break-before-make) as standard — adjustable neutral position delay prevents out-of-phase load transfers for full equipment protection
  • Optional closed transition (make-before-break) for seamless transfers with zero interruption time
  • Solid neutral standard on 4-wire systems
  • Heavy-duty brushless gearmotor and operating mechanism for extended service life and mechanical reliability
  • Bypass isolation option available for 400–1200A units — allows maintenance without interrupting power to the load
  • TSC 7320 microprocessor digital controller with 2.3″ backlit LCD for real-time monitoring of voltage, frequency, and load status
  • Front-panel editing with PIN protection and customizable status screens
  • Fully adjustable time delays for engine start, engine cool-down, transfer, and retransfer
  • Five pre-programmed output contacts for core ATS functions: Load on Utility, Load on Generator, Load Disconnect, Fail to Transfer, and ATS Not in Auto
  • 8 programmable digital inputs (voltage-free) for custom site integration
  • 2-wire dry contact for automatic generator start — integrates with most standby generator systems
  • Built-in programmable exerciser timer for scheduled on-load or off-load testing
  • Local and remote utility power failure simulation test capability
  • Under/over frequency protection for both utility and generator sources
  • Three-phase overvoltage, phase loss, phase unbalance, and phase sequence/rotation protection
  • Generator bus power metering capability (amps, volts, frequency, kW, kVA, power factor)
  • RS485 Modbus remote communication port for system integration
  • Control circuit isolation plug for safe disconnection from all power sources
  • Meets NFPA 110 requirements for emergency and standby power systems
  • UL 1008 and CSA C22.2 No. 178 listed

Applications:

  • Commercial and industrial facilities
  • Healthcare and hospital critical systems
  • Data centers and mission-critical infrastructure
  • Wastewater treatment and utility operations
  • Manufacturing and industrial plants
  • Commercial and institutional buildings

Voltage Range: 120V to 600VAC, 3-phase, 50/60Hz